Factory Ceiling Height vs Clear Height in Rawang, Serendah and Shah Alam: What 30 ft, 40 ft, 12 m and 15 m Suit, Racking Levels and Column Spacing

Written by , PEA 1478 · Published · Power, height, floor and access

Short answer

Ceiling height is usually measured to the top of the roof; clear height to the lowest thing under it, such as a sprinkler pipe or light, and only clear height decides what fits. About 30 ft (9.1 m) suits production with some racking, 40 ft or 12 m reach-truck racking, and 15 m needs very narrow aisle trucks.

Illustrative image of a tall steel warehouse with its roller shutter open onto empty pallet racking, beside a much lower row of terrace factories, with green hills behind.
Illustrative image

Key Takeaways

  • Three heights, three different numbers. Ceiling or apex height runs from the floor to the top of the roof, eaves height to where the side wall meets the roof, and clear height to the lowest thing under the roof: a haunch, a beam, a sprinkler pipe or a light. Only clear height tells you what fits.
  • What each height suits. About 30 ft (9.1 m) clear suits production with some racking. 40 ft (12.2 m) or 12 m suits high racking worked by reach trucks, which Toyota says lift to about 13 m. 15 m calls for very narrow aisle trucks or automation.
  • Higher is not always better. For a single-storey store of combustible goods, the UBBL fire table counts cubic metres as well as floor area: a 5,000 m² store passes 70,000 m³ once its average internal height is above 14 m, and that row adds a pressurised hydrant system.
  • Height costs steel, floor and fire protection. In a European steel design table, a 30 m span frame moves from an IPE 600 column at 6 m eaves to a deeper IPE 750 at 10 m, and Selangor's 1986 by-laws asked for storage floors of at least 2.4 kN/m² for every metre of storage height.
  • In my areas, tall usually means detached. Selangor's 2016 planning manual capped terrace factories at 40 ft (12.2 m), and terrace units make up most registered factory deals in the Serendah area, so a tall racked warehouse means a detached unit or land to build on.

What do ceiling height, eaves height and clear height mean?

People use "ceiling height" loosely. When an owner tells me a unit has a "40 ft ceiling", my first question is: measured from the floor to where? A steel factory or warehouse has three heights, and they can differ by metres.

  • Ceiling or apex height is the distance from the floor to the highest point of the roof, at the ridge. It is the highest of the three figures and the least useful one for storage, because the roof slopes down from it.
  • Eaves height is the distance to the point where the side wall meets the roof. European steel design guidance measures it from the column base to the rafter centreline and gives 5 to 10 m as typical for a single-span portal frame, with 7.5 m commonly adopted (Steel Buildings in Europe, Part 2: Concept Design).
  • Clear height is the distance from the finished floor to the underside of the lowest obstruction: the haunch where the rafter meets the column, a roof beam, a crane beam, sprinkler pipes, ducting or lights. SteelConstruction.info measures a portal frame's clear height from the top of the floor to the underside of the haunch and puts it between 8 and 18 m.

Malaysian building law draws the same line. The Selangor Uniform Building By-Laws define "headroom" as the clear vertical distance between the finished floor level and the soffit of the lowest projecting member or surface above, and the height of a room as the distance from the finished floor to the underside of the ceiling. By-law 44(6) says any factory room in which a person works must have at least 3 metres of headroom (Selangor UBBL 1986, updated text). That 3 m is the legal minimum for people, not a guide to storage.

Why is the clear height lower than the figure in the advert?

Because a factory roof is pitched and things hang from it.

  • The roof slopes. A portal frame roof is usually pitched at 5 to 10 degrees, 6 being common, so on a wide building the ridge sits well above the eaves.
  • Haunches hang lowest beside the walls. The eaves haunch is generally 10% of the span long, and its underside sits about 2% of the span below the rafter axis (SteelConstruction.info). On a 30 m span, that is a haunch running about 3 m in from each wall and hanging about 0.6 m lower, right where wall racking would stand.
  • Services take their share. Sprinkler mains, lights, cable trays and ducting all sit under the steel. The sprinkler designer also needs a gap between the sprinkler heads and the top of the stored goods, and that gap comes off your stacking height. Its size depends on the sprinkler system, so ask the M&E engineer rather than assume one.
  • Cranes. Where there is an overhead crane, what counts is the hook height under the crane beam, not the roof.

On a viewing I measure with a laser at the lowest point of each bay, not in the middle of the floor, and I note what the obstruction was.

What do 30 ft, 40 ft, 12 m and 15 m buildings suit?

Clear height Converted What it usually suits What to check
30 ft 9.1 m Production lines with storage, workshops, pallet racking worked by reach trucks How many levels your load height allows; the forklift's lift height
40 ft 12.2 m Warehousing and distribution with high racking Reach trucks lift to about 13 m; Selangor's 2016 manual capped terrace factories at 40 ft, so this needs a detached or semi-D building
12 m 39.4 ft The same band as 40 ft; new logistics buildings in Shah Alam advertise it The floor rating and a fire system designed for that storage height
15 m 49.2 ft High-bay storage with very narrow aisle trucks or automated systems Truck lift height, floor flatness and loading, fire volume thresholds

Two examples from pages I read. In Shah Alam, a December 2025 advertorial in The Star for Parkwood Holdings' Avant Industrial Park on Jalan Renggam 15/5 states a clear ceiling height of 11 to 12.3 m and a floor rated at 30 kN/m². That is the Seksyen 15 side of town. For trucks, Toyota says its reach trucks reach up to about 13 m and need an aisle of about 2,800 mm, while a man-up very narrow aisle truck such as Jungheinrich's EKX 516 lifts up to 18,000 mm with a 1,600 kg load. So 12 m sits within reach-truck range, and 15 m usually means a different fleet.

How many racking levels fit under a given clear height?

I work it out from the client's own pallet load height, not from a rule of thumb:

levels = (clear height minus the sprinkler gap) ÷ (load height + beam depth + the lift gap the forklift needs)

The beam depth and lift gap come from the racking supplier and the forklift data sheet. Dividing the clear height by the load height alone gives the ceiling before those deductions. For loads 1.5 m tall:

  • 9.1 m (30 ft): 9.1 ÷ 1.5 = 6.07, so six levels at most, counting the floor position, and fewer in practice.
  • 12.2 m (40 ft): eight levels at most.
  • 15 m: ten levels at most.

So every 3 m of extra clear height buys at most two more levels of 1.5 m loads. Whether those levels pay depends on the truck you will run and on the floor. Selangor's 1986 by-laws set storage floors at no less than 2.4 kN/m² for each metre of storage height (Selangor UBBL 1986, Fourth Schedule): 21.6 kN/m² for 9 m of goods and 28.8 kN/m² for 12 m. Today by-law 59 sends imposed floor loads to MS EN 1991-1-1, and by-law 60 asks for special provision in the floor design where forklifts may be used (Selangor UBBL, updated text), so the figure that counts is on the structural plans. FactoryHub's floor loading calculator gives a first estimate, and my floor loading guide explains how I check a slab.

What does column spacing mean, and is a column-free building worth paying for?

Steel portal frames are widely used for single-storey factories and warehouses: pairs of columns joined by a pitched rafter, repeated along the building. The European guide gives a typical single span of 15 to 50 m, with 25 to 35 m the most efficient, and frames 5 to 8 m apart (Steel Buildings in Europe). Inside one span there are no columns at all; the columns stand along the walls, one every 5 to 8 m.

A building wider than one span repeats the frame with internal columns. To reduce them, the same guide allows removing every second internal column, or keeping one every third frame, with a deep "valley" beam carrying the rafters between the remaining columns.

What a column-free floor gives you, and what it costs:

  • racking runs and aisles can go wherever the operation needs them;
  • forklifts, trailers and long loads move without working around posts;
  • a production line can be re-laid, or a different tenant can move in later, more easily;
  • but longer spans need deeper rafters and longer haunches, so more steel goes in and more height is lost near the walls.

Where columns are unavoidable, what matters is where they fall. I lay the racking plan over the column grid and check that internal columns land inside rack runs, not in aisles, and that the spacing along the walls takes whole rack bays. Under by-law 10, building plans must give figured dimensions between walls, piers and stanchions, and the sections must show the height of storeys (Selangor UBBL, updated text), so the grid is on paper before I measure it.

Is a higher factory always better?

No. Extra height is worth paying for only if you will stack into it.

  • Production on the floor gains little. Assembly lines, machine shops and food processing mostly work at floor level; they need headroom, crane hook height and ventilation more than 12 m.
  • The fire table counts volume for storage. The UBBL Tenth Schedule rows for single-storey warehouses of combustible goods use cubic metres as well as floor area. From 1,001 to 10,000 m² and 7,001 to 70,000 m³ they list automatic sprinklers, hose reels, a manual fire alarm and automatic fire monitoring; above 10,000 m² or 70,000 m³ they add a pressurised hydrant system (UBBL, Tenth Schedule). Take a 5,000 m² store (about 53,800 sq ft): at an average 9 m it holds 45,000 m³; at 15 m it holds 75,000 m³ and moves to the hydrant row. The single-storey factory rows, by contrast, count floor area only.
  • Bomba counts volume too. A storage building of 1,000 m² or more, or 7,000 m³ or more, fitted with automatic sprinklers is a designated premises that needs a fire certificate (Palcon). My Bomba requirements guide covers who pays for which system.
  • Very tall roofs need special sprinklers. A Malaysian fire engineering firm notes that sprinklers more than 17 m above the floor are classed as ineffective, and that sprinkler design depends on ceiling height, storage height and sprinkler head type (IPM).
  • More air to move. For the same floor, a taller building has more volume to ventilate or cool.

Why do high-ceiling factories cost more to build, buy or rent?

  • Heavier steel. In the European guide's preliminary sizing table, a 30 m span frame with unrestrained columns and a 10 kN/m rafter load needs an IPE 600 column at 6 m eaves and an IPE 750 at 10 m (Steel Buildings in Europe, Table 8.1). The same guide notes that wind can matter early in the design if the portal frame is tall.
  • More wall. Every extra metre of height adds cladding all round the building.
  • A stronger floor. High racking puts more weight on each square metre, as the 2.4 kN/m² per metre rule shows.
  • More fire protection. Sprinklers, hydrants and special heads arrive sooner in a tall store, as above.

What a buyer or tenant pays for that is harder to pin down. JPPH-registered deals record price, land area and factory type, not clear height. In Shah Alam, registered detached factory deals over 24 months had a median price of RM16 million, a typical range of RM13.61 million to RM36.2 million, and RM335 psf of land (FactoryHub, Shah Alam transactions). Height is one of the things inside that spread, with size, age, power and location, and the records do not say how much of it. When a seller asks extra for height, I ask the valuer for deals on buildings of a similar specification rather than accept a premium on trust.

What do I check on a viewing in Rawang, Serendah and Shah Alam?

  1. The approved building plans and the CCC or CF. The plans sit with the council: Majlis Perbandaran Selayang (MPS) for Rawang and Kundang, Majlis Perbandaran Hulu Selangor (MPHS) for Serendah, Sungai Choh, Bukit Beruntung and Batang Kali, and Majlis Bandaraya Shah Alam (MBSA) for Shah Alam. The sections give the heights; the floor plans give the column grid.
  2. Whether the building still matches the plans. A mezzanine, a raised roof or an extension added later changes both the height and the approval status; my guide on unapproved extensions covers that.
  3. A laser measurement at the lowest point under the haunches, sprinkler pipes, lights and crane beams, plus the eaves and the ridge.
  4. The column grid against the racking drawing, bay by bay.
  5. The sprinkler system, and the storage height it was designed for.
  6. The floor's design load in kN/m², from the structural plans.
  7. Door openings against the tallest truck and load you will bring in.

Where I look depends on the height. In the Serendah area, which takes in Bukit Beruntung, registered deals over 24 months were 256 terrace factories against 28 semi-D and 8 detached (FactoryHub, Serendah transactions), and Selangor's 2016 manual set a maximum building height of 40 ft (12.2 m) for terrace factories (Selangor planning manual, third edition). PLANMalaysia@Selangor has since approved a fourth edition in June 2022 and a new set of state guidelines in November 2025, which I have not been able to read in full, so I confirm the current rule with the council's planning department. For 12 m of clear height in the north, I look at detached factories in Rawang or at industrial land in Serendah to build on, and in Shah Alam at newer warehouses for rent. My detached, semi-D and terrace comparison explains the wider trade-offs.

Where to find 12 m and 15 m clear height

Where are there factories with 12 meter clear height in northern Selangor or Shah Alam?

Mostly in detached or semi-D factories, because Selangor's 2016 planning manual caps terrace factories at 40 ft (12.2 m), so a terrace unit rarely gives 12 m clear. In the north, look at detached factories in Rawang under MPS, or industrial land in Serendah under MPHS to build on; in Shah Alam, look at newer logistics warehouses under MBSA. Check the clear height on the approved section drawings, then measure it on site at the lowest point.

Where are there warehouses with 15 meter clear height in Selangor?

Mostly in newer logistics warehouses in Shah Alam under MBSA, or in detached units and land to build on in Rawang under MPS and Serendah under MPHS. A 15 m clear height means high-bay storage run by very narrow aisle trucks or automation. Check three things before committing: the truck's lift height, the floor design load in kN/m², and the fire volume threshold, because a tall store can pass 70,000 m³ and then needs a pressurised hydrant system.

  • How do you determine whether a factory is suitable for an automated production line? Check four things: clean TNB power quality, a floor flat enough for AGVs and VNA trucks, enough clear height, and fibre connectivity.
  • What is a Smart Factory? It is an IoT-ready industrial building with strong power capacity and fibre connectivity, able to support Malaysian Smart Factory 4.0 operations.
  • What building conditions are required for an automated factory? It needs clean TNB power quality, a flat floor for AGVs and VNA trucks, sufficient clear height and fibre connectivity.
  • How will AI and robotics change factory requirements? As physical AI moves onto factory floors, Malaysian industrial buildings will need updated standards for power, insulation and hardware.

These questions are answered in full on FactoryHub.

To have clear height and column spacing checked against your racking plan before you sign, WhatsApp Jason Low (Probationary Estate Agent PEA 1478, CID Realtors Sdn Bhd) on +60 12-288 1834.

Questions people ask

01What does ceiling height mean in a factory listing?+

It usually means the distance from the floor to the top of the roof, or sometimes to the eaves, and listings rarely say which. Neither tells you what fits inside. Ask for the clear height, measured from the finished floor to the lowest haunch, beam, sprinkler pipe or light, and check it on the approved section drawings.

02Is clear height the same as eaves height?+

No. Eaves height is measured to where the side wall meets the roof, while clear height is measured to the underside of the lowest obstruction, such as the haunch at the top of the column or the sprinkler pipes. Clear height is the lower figure and the one that decides how high you can stack.

03What is the minimum ceiling height for a factory in Malaysia?+

The Selangor Uniform Building By-Laws, by-law 44(6), require at least 3 metres of headroom in any factory room in which a person works. Headroom is measured from the finished floor to the soffit of the lowest projecting member above. That is a minimum for people; storage and racking need far more.

04How many pallet levels fit in a 12 m warehouse?+

Divide the clear height, less the sprinkler gap, by your load height plus beam depth and lift gap. With 1.5 m loads, 12 m gives eight levels at most before those deductions, and fewer in practice. Reach trucks lift to about 13 m, so the truck is rarely the limit at 12 m; the floor rating and sprinkler design often are.

05Does a taller warehouse need more fire protection?+

Often yes. For single-storey warehouses of combustible goods, the UBBL Tenth Schedule counts cubic metres as well as floor area, and above 70,000 m³ it adds a pressurised hydrant system. Bomba also treats a sprinklered storage building of 7,000 m³ or more as a designated premises that needs a fire certificate.

06How do I find a unit's clear height before a viewing?+

Ask the owner for the approved building plans: under by-law 10 the sections must show storey heights and the plans the dimensions between columns. Then have the height measured with a laser at the lowest point under the haunches, sprinkler pipes and lights, not at the middle of the roof.

07Where can I find factories for rent in Rawang, Serendah or Shah Alam with high ceilings?+

Look at detached factories first, because high ceilings are rare in terrace units. Selangor's 2016 planning manual capped terrace factories at 40 ft (12.2 m), and terrace units make up most registered factory deals in the Serendah area. For real height, the places to look are detached factories in Rawang, industrial land in Serendah to build on, and newer warehouses in Shah Alam. Ask for the clear height, not the ceiling height, and check it on the approved section drawings.

08Where in Rawang, Serendah or Shah Alam can I find warehouses suitable for automated storage systems?+

Look for clear height of around 15 m, which in northern Selangor usually means a detached factory, because very narrow aisle and automated trucks lift far higher than reach trucks and Selangor's 2016 planning manual capped terrace factories at 40 ft (12.2 m). Check the approved plans with MPS for Rawang and Kundang, MPHS for Serendah, Sungai Choh, Bukit Beruntung and Batang Kali, or MBSA in Shah Alam. Also confirm the floor and the sprinkler system were designed for that storage height.

Sources

  1. Selangor Uniform Building By-Laws 1986, updated text (KPKT): by-law 2 definitions of headroom and height, by-law 10 plan contents, by-law 44(6) factory headroom, by-laws 59 and 60 floor loads and mechanical stacking
  2. Selangor Uniform Building By-Laws 1986 as first made (KPKT): Fourth Schedule imposed floor loads for storage per metre of storage height
  3. Uniform Building By-Laws 1984 as amended (OSHWARE text): Tenth Schedule rows for single-storey factories and warehouses of combustible goods
  4. Palcon: Perakuan Bomba, designated premises for factories and storage under the Fire Services Act 1988
  5. IPM Professional Services: automatic fire sprinkler systems in Malaysia, UBBL by-law 228 and MS 1910, sprinklers above 17 m
  6. Manual Garis Panduan dan Piawaian Perancangan Negeri Selangor, third edition (2016), industrial chapter IND2 and IND3 (copy hosted by REHDA Institute)
  7. PLANMalaysia@Selangor: editions of the Selangor planning manual (2016, 2022) and the 2025 state planning guidelines
  8. SteelConstruction.info: Portal frames, typical span, clear height, frame spacing and haunch proportions
  9. Steel Buildings in Europe, Single-Storey Steel Buildings Part 2: Concept Design, sections 3.1, 3.4, 3.6.6 and Table 8.1
  10. Toyota Material Handling: reach trucks, lift height and aisle width
  11. Jungheinrich UK: EKX 516 very narrow aisle truck, lift height and capacity
  12. The Star (2 December 2025, advertorial): Avant Industrial Park, Jalan Renggam 15/5, Shah Alam
  13. FactoryHub: Shah Alam JPPH-registered industrial transactions
  14. FactoryHub: Serendah JPPH-registered industrial transactions
  15. FactoryHub: floor loading calculator

Units on the market nearby

More on power, height, floor and access

All guides: Power, height, floor and access →

Probationary Estate Agent · PEA 1478 · CID Realtors Sdn Bhd E(1) 1855About Jason → · Contact →