Does a Factory Need a Dock Leveller? Roller Shutter Size, Number of Exits and Staff Parking for a Factory in Rawang, Serendah or Shah Alam
A factory needs a dock leveller only when it loads from a raised dock. Size the roller shutter from the widest and tallest load. Selangor's by-laws ask for at least two exits, 5 m apart, from every storey and fire compartment, and the 2016 Selangor manual asks for 1 car bay per 1,000 sq ft of production floor.
Key Takeaways
- A dock leveller is needed only when you load from a raised dock. No Selangor rule requires one. It matters when forklifts drive from a dock into closed containers or box lorries; at a ground-level terrace or semi-D factory, loading from the yard is normal.
- Size the roller shutter from the widest and tallest load that passes through it. An ISO container's door opening is at least 2,337 mm wide and 2,261 mm high, or 2,565 mm on a high cube; a lorry that drives inside needs far more height. A shutter in a compartment wall must be a fire-rated door.
- Every storey and every fire compartment needs at least two exits, at least 5 m apart. The Selangor Uniform Building By-Laws also cap the walk to an exit at 30 m in an unsprinklered general factory and 60 m with sprinklers.
- The 2016 Selangor planning manual sets car parking by floor use: 1 car bay per 1,000 sq ft of production floor, 1 per 2,500 sq ft of store and 1 per 500 sq ft of office, plus 10% for visitors.
- The council's approved plan has the final word. Selangor has approved newer planning standards since 2016, so I always confirm the current figures with the council's planning department.
Does a factory need a dock leveller?
Only if you load or unload from a raised dock. A dock leveller is a hinged steel plate set into the edge of a loading dock that bridges the gap between the warehouse floor and the deck of the lorry or container trailer, so a forklift or pallet truck can drive straight in. No by-law or Selangor planning standard makes one compulsory for a factory or warehouse.
Most terrace and semi-detached factories in Rawang, Serendah, Bukit Beruntung and the older Shah Alam sections have their floor close to the yard level. There a forklift loads the lorry from the side or the rear, and a leveller would have nothing to bridge. When a client asks me whether they need one, I ask three questions:
- Do your goods travel in closed containers or box lorries loaded from the rear? A forklift then has to drive into the container, which is only practical from a dock at deck height, with a leveller or a mobile ramp in the yard.
- How many loads a day? A logistics or fast-moving consumer goods operation moving many containers a day gains a great deal from a dock; a workshop sending out a few lorries a week does not.
- What trailers does your haulier use? Deck heights differ between trailers, so ask the haulier for theirs before you pick a dock or leveller.
Two checks follow if the factory has docks. A container's floor is rated under ISO 1496/I for a forklift with an axle load of up to 5,460 kg, according to Hapag-Lloyd's container specification, so compare that with your forklift's laden axle load. And a leveller is a machine with hydraulics and lips that wear: in a rented factory the agreement should say who services and repairs it, a point I cover in who pays for repairs in a rented factory.
What size roller shutter does a factory need?
Size the roller shutter from the widest and tallest thing that will pass through it, then add working clearance. There is no planning or building by-law figure for a loading shutter, so I start from what will actually move through the opening:
| What passes through | Figure to start from | Source |
|---|---|---|
| Forklift loading into a container at a dock | Container door opening at least 2,337 mm wide, 2,261 mm high (standard) or 2,565 mm (high cube) | ISO 668 table in Hapag-Lloyd's specification |
| Container trailer parked inside or under a canopy | Container outside height 2,591 mm (standard) or 2,896 mm (high cube), before the trailer deck | Same |
| Lorry driving under a loading canopy | PLANMalaysia asks for at least 4.5 m of headroom on a flat platform and 4.75 m on a ramp | PLANMalaysia parking guideline 2017 |
At a dock, the shutter must clear the forklift with its mast and the tallest pallet it carries, so check the forklift's own height figures. Where lorries drive inside the building, I treat the 4.5 m canopy headroom as the reference for the shutter's clear height. On a viewing I measure the clear opening with the shutter fully rolled up: the guides, the motor box and the bottom bar always take some width and height off the size printed on the plan.
Fire rules apply too. The Selangor Uniform Building By-Laws define a "door" to include any shutter, and by-law 162 requires an opening in a compartment wall or separating wall to be protected by a fire door with the fire resistance that wall needs, built to MS 1073 under by-law 163. So a shutter between two compartments, or between your unit and the next terrace unit, is fire-rated equipment, not just a door. Widening an opening or adding a shutter is building work: in a rented unit it needs the landlord's consent first, and may need the council's approval, as I explain in factory renovation and reinstatement works. For the gate, the drain crossing and the turning space outside the shutter, see can a 40-footer reach your factory.
How many entrances and exits does a factory need?
At least two separate exits from every storey, and at least two storey exits from every fire compartment, placed at least 5 m apart. That is the rule in the Selangor Uniform Building By-Laws 1986: by-law 166 asks for not less than two separate exits from each storey, by-law 167 for at least two storey exits from every compartment, as far apart as practical and not less than 5 m, and by-law 174 says each exit must lead directly to a final exit, a protected staircase or an external route. More exits are needed when the floor is too big for the walking distance or too full for the exit width.
How far you may walk to an exit. The Seventh Schedule sets the limits for a factory where alternative exits are available:
| Use | Dead-end limit | Unsprinklered | Sprinklered |
|---|---|---|---|
| Factory, general and special purpose | 15 m | 30 m | 60 m |
| Factory, high hazard | 0 m | 22 m | 35 m |
| Storage, low and ordinary hazard | 15 m | 30 m | 60 m |
| Storage, high hazard | 10 m | 20 m | 35 m |
The distance is measured along the natural walking path around machines and racks, and in open areas the straight-line distance may not exceed two-thirds of the permitted travel distance (by-law 165). This is why a long unsprinklered building often needs exits along its sides, not only at the two ends.
How wide the exits must be. The same schedule counts a factory at 10 m² of gross floor area per person and lets 100 people use each unit of exit width through doors to the outside, a unit being 550 mm, with access to an exit at least 700 mm wide. On my arithmetic, a 2,000 m² factory floor counts as 200 people, which needs two units, or 1,100 mm of exit width in total.
The doors themselves. By-law 173 says exit doors must open from the inside without a key or special knowledge, close by themselves, and release on power failure or when the fire alarm goes. A loading shutter that is padlocked or needs power to open does not meet that, so I do not count it as an exit unless the approved plan does. The fire systems that go with these exits are in my Bomba requirements for a factory or warehouse, and the certificate itself in the Bomba fire certificate guide.
How many employee parking spaces does a factory need?
It depends on the floor area and its use. The Selangor planning manual, third edition (2016) sets these standards for detached, semi-detached and terrace factories:
- Cars: 1 bay per 1,000 sq ft (92.9 m²) of production floor, 1 per 2,500 sq ft (232.2 m²) of store and 1 per 500 sq ft (46.4 m²) of office, each plus 10% for visitors.
- Motorcycles: 1 bay per 2,000 sq ft (185.8 m²) of gross floor area, or 1 per worker.
- Lorries: 1 bay per 10,000 sq ft of a detached or semi-detached factory, at least 2; 1 bay for every 5 terrace factories.
- Buses: large industries with many workers should provide space for buses and a lay-by inside the compound.
A worked example on my arithmetic: a 20,000 sq ft detached factory with 15,000 sq ft of production, 2,500 sq ft of office and 2,500 sq ft of store needs 15 + 5 + 1 = 21 car bays, plus 2.1 for visitors, so about 23; 10 motorcycle bays on floor area; and 2 lorry bays.
PLANMalaysia's national parking guideline of 2017 counts differently: for a detached or semi-detached factory on a lot under 1 acre, 1 car bay per 150 m² of floor, plus 1 per 50 m² of administration space, 10% for visitors, 1 motorcycle bay per 100 m², and 1 bus bay per 150 workers or a lay-by for every 90 to 150 workers (at most 3). On lots over 1 acre it is 1 car bay per 250 m². Which standard applies is the council's decision, and Selangor has approved newer editions of its manual in 2022 and in 2025 (approved on 7 November 2025 and confirmed on 12 November 2025, according to PLANMalaysia Selangor); the 2025 edition is sold in print, so ask MPS, MPHS or MBSA for the figure that applies to your plan.
In practice the bigger question is your own staff. I ask a client how many people work each shift, how many come by car and how many by motorcycle or company bus, and whether two shifts overlap at changeover, because that is when the car park fills. Then I check that the bays on the approved layout still exist: in older estates they are often lost to containers, pallets or an unapproved extension.
What I check on a viewing
- The approved building plan: number and position of exits, fire compartments, and parking bays.
- The clear opening of each roller shutter, fully rolled up, against your forklift, pallets and lorries.
- Whether the docks have levellers, their service records, and who maintains them under the agreement.
- That every exit door opens from inside without a key, and that no exit route is blocked by racking.
- The walking distance from the far corner of the floor to the nearest exit, against the limits above.
- How many cars and motorcycles the yard really takes once the lorry bays and turning space are kept clear.
If you are comparing loading, exits and parking between factories in Rawang, Serendah or Shah Alam, WhatsApp Jason Low, Probationary Estate Agent PEA 1478 with CID Realtors Sdn Bhd, on +60 12-288 1834.
Questions people ask
01Does a factory need a dock leveller?+
Only if goods are loaded from a raised dock, usually into closed containers or box lorries with a forklift. No Selangor by-law or planning standard requires one, and most ground-level terrace and semi-D factories load from the yard instead. Ask your haulier for its trailer deck height before choosing a dock or leveller.
02What size roller shutter does a factory need for 40 ft containers?+
Start from what passes through: an ISO container's door opening is at least 2,337 mm wide and 2,261 mm high, or 2,565 mm on a high cube, and the forklift mast and pallets must clear the shutter. If lorries drive inside, PLANMalaysia's 4.5 m canopy headroom is a sensible reference for the clear height. Measure the clear opening with the shutter fully rolled up.
03How many exits does each floor of a factory need in Selangor?+
At least two separate exits from each storey, and at least two storey exits from every fire compartment, at least 5 m apart, under by-laws 166, 167 and 174 of the Selangor Uniform Building By-Laws. More exits are needed when the travel distance or the exit width would otherwise exceed the Seventh Schedule limits.
04What is the maximum travel distance to an exit in a factory?+
For a general or special purpose factory with alternative exits, 30 m without sprinklers and 60 m with sprinklers, with a dead-end limit of 15 m. A high hazard factory is limited to 22 m and 35 m with no dead end allowed. The distance is measured along the walking path around machines and racks.
05How many car parks does a factory need in Selangor?+
The 2016 Selangor planning manual asks for 1 car bay per 1,000 sq ft of production floor, 1 per 2,500 sq ft of store and 1 per 500 sq ft of office, plus 10% for visitors, and 1 motorcycle bay per 2,000 sq ft or per worker. Newer Selangor editions were approved in 2022 and 2025, so confirm the current rate with the council.
06Can a roller shutter count as an emergency exit?+
Usually not. By-law 173 requires exit doors to open from inside without a key, close by themselves and release on power failure or fire alarm, which a padlocked or motorised loading shutter does not do. Count only the exits shown on the approved building plan.
Sources
- Selangor Uniform Building By-Laws 1986 (updated): by-laws 162 to 174 (fire doors, exits, storey exits, exit doors) and Seventh Schedule travel distance and exit capacity
- Manual Garis Panduan dan Piawaian Perancangan Negeri Selangor, third edition (2016), industrial chapter IND1 to IND3: car, motorcycle and lorry parking, loading space (copy hosted by REHDA Institute)
- PLANMalaysia@Selangor: Manual Garis Panduan dan Piawaian Perancangan Negeri Selangor editions (2016, 2022, 2025 approved 7 November 2025 and confirmed 12 November 2025)
- PLANMalaysia: Garis Panduan Perancangan Tempat Letak Kenderaan (2017), lorry bays, canopy headroom and industrial parking standards
- Hapag-Lloyd: Container Specification, ISO 668 dimensions and door openings, container floor forklift axle load
Units on the market nearby
Semi-D Factory for Rent in Saujana Teknologi Rawang, Rawang, 6,525 sq ft
RM 10,500/month
Semi-Detached Factory for Sale or Rent in Saujana Rawang, Rawang, 8,000 sq ft
RM 4,000,000 · RM 15,000/month
Detached Factory for Rent in Batu 17 Rawang, 9,000 sq ft
RM 21,000/month
More on choosing an area or industrial park
- E-Metro Logistics Park, Bukit Raja: Metrohub Specs, Occupancy and What Tenants Should Check
- MIEL Batang Kali Industrial Area (Kawasan Perindustrian MIEL): What to Check Before You Buy or Rent a Factory
- Rawang or Serendah for a New Factory: Land, Power, Access and Approvals Compared
- Factory Near Perodua in Sungai Choh: What Automotive Suppliers Should Check